Features
● High accuracy
● No mechanical and movable parts, little repair work
● Span and zero continuous and adjustable from outside
● Good stability
● Positive shift amount to 500%; negative shift 600%
● Two-wire system 4~20mA DC
● Damping adjustable, overpressure protection
● Solid components, patch-type printed circuit board
● Explosion-proof structure, all-day use
● Unified structure, strong interchangeability of parts
● Miniaturization(total height 166mm)
● Diaphragm materials of contacting mediums option (316L, TAN, HAS-C, MONEL, etc.)
● smart HART protocol
● Service: liquid, gas and steam
● Measuring range : 0~0.06 kPa to 0~40Mpa
● Output signal : 4~20mA DC (four-wire 220V AC power supply, 0~10mA DC output for special)
● Power supply : 12~45V DC, generally 24V DC
● Features of loading: relation equation of loading impedance RL and power voltage
Vs: RL <= 50(Vs-12)
● Indicator : pointer-type linearity indication 0~100% scale mark or LCD indicator, LED indicator.
● Explosion proof : a. explosion isolation d II BT4
b. intrinsically safe ia II CT6
● Positive and negative shifts : after positive and negative shifts of zero absolute values of upper-and-lower-limit values of span and measuring range not exceed 100% of upper limit of measuring range.( smart type : turn down ratio 20:1, 40:1)
Maximum positive shift is 500% of minimum adjusting span; maximum negative shift is 600% of minimum adjusting span.
● Temperature range: amplifier operation temperature range: -29 ~ +93C
(LT type: -25 ~ +70C); measuring component of fill silicone oil: -40 ~ +104C
flange type transmitter fill hi-temperature silicone oil: -20 ~ +315C normal silicone oil: -40 ~ +149C
● Static pressure : 4, 10, 25, 32Mpa
● Humidity : relative humidity 0~100%
● Volume absorption : < 0.16cm3
● Damping (phase step response) : For silicone oil, generally between 0.2s and1.67s, continuous and adjustable
(no shift, under standard operation conditions, fill silicone oil, 316 SS diaphragm)
1. Accuracy class: +/-0.25%, +/-0.5% (smart type: +/-0.1%, +/-0.075%)
2. Dead zone: no (<=0.1%)
3. Stability : within 6 months not beyond absolute value of basic error of maximum span
4. Vibration effect: on a random ax upward, at vibration frequency of 200 Hz, error +/-5%/g of upper limit of measuring range.
5. Power effect : < 0.005%/V of output span
6. Loading effect : no effect from loading at stable power
7. Effect of installation position : at most 0.24kPa of zero error, no effect on span
Others
1. Diaphragm: 316 SS, HC -276, Monel or Ta
2. Exhaust/vent Valve: 316 SS, HC or Monel
3. Flange and Connector: 316 SS, HC or Monel
4. Contacting medium “O” ring: acrylotrile-butadiene rubber, fluorine rubber
5. Fill liquid: silicone oil or inert oil
6. Blot: 316 SS
7. Electronic Body Material: low copper-aluminum alloy
8. Ignition Voltage Connection Fit : flange NPT 1/4, center distance 54mm; connector NPT 1/2 or M20 ×1.5 male round-cone surface sealed, when carrying connector the center distance 50.8, 54, 57.2mm (NPT taper thread accords with GB/T12716-91)
9. Signal line connecting hole : G 1/2"
10. Weight : 4 kg (standard type)
JCDP he transmitter.
Features
Transmitters with remote device are suitable for the following operation conditions:
v Mediums with high temperature should be isolated with transmitter.
v Measured mediums have corrosion to sensitive scripts of transmitters.
v Suspending liquid or mediums with high viscosity
v Measured mediums solidize or crystalize due to change of environment or technological process temperature.
v Strict purification of measuring head is needed for replacing measured mediums
v Measuring head must be kept clean and sanitary.
v Seal pressure container measurement.
Measuring Range
(Specifications of flange and capillary tube are shown in the additional sheet)
1. Remote double flush flange 4. Remote one-flush & one-insertion
JCDP-4420 0-6-36kPa flange type
JCDP-4520 0-30-180kPa JCDP-4350 0-1.2-7.2kPa
JCDP-4620 0-160-1000kPa JCDP-4450 0-6-36kPa
JCDP-4720 0-400-2500kPa JCDP-4550 0-30-180kPa
JCDP-4820 0-1600-10000kPa JCDP-4650 0-160-1000kPa
2. Remote single flush flange JCDP-4750 0-400-2500kPa
(pressure type)
JCDP-1410 0-6-36kPa 5. Remote single insertion flange
JCDP-1510 0-30-180kPa type (pressure type)
JCDP-1610 0-160-1000kPa JCDP-1330 0-1.2-7.2kPa
JCDP-1710 0-400-2500kPa JCDP-35-1430 0-6-36kPa
JCDP-1810 0-1600-10000kPa JCDP-1530 0-30-180kPa
JCDP-1630 0-160-1000kPa
3. Remote double insertion flange type JCDP-36-1730 0-400-2500kPa
JCDP-4340 0-1.2-7.2kPa JCDP-1830 0-1600-10000kPa
JCDP-4540 0-30-180kPa
JCDP-4640 0-160-1000kPa
JCDP-4740 0-400-2500kPa
Structure Materials
1. Remote measuring head, capillary tube and fill liquid
2. Diaphragm and exhaust/vent valve : 316 stainless steel
3. Remote transmission side flange : carbon-steel plating cadmium or 316 stainless steel
4. Flange or blot : carbon-steel plating cadmium
5. Fill liquid: silicone oil or inert liquid
6. O ring : fluorine rubber
7. Electrical shell : low copper-aluminum alloy
Electrical Connection
NPT1/2 Female ( or to be specified by you)